Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chinese Journal of Urology ; (12): 23-27, 2022.
Article in Chinese | WPRIM | ID: wpr-933156

ABSTRACT

Objective:To explore the feasibility and safety of robot-assisted retrohepatic inferior vena cava(IVC) tumor thrombectomy for renal tumor patients with a single position.Methods:The clinical data of 6 renal tumor patients with retrohepatic IVC thrombus (5 males and 1 female, mean age of 58 years) who underwent robot-assisted retrohepatic IVC tumor thrombectomy with a single position in First Affiliated Hospital of Zhengzhou University from December 2015 to August 2020 were retrospectively reviewed. Four cases had the renal tumor on the right side and two on the left side. The mean tumor size was 9.6 cm(range 7-13 cm). There were 4 cases of Mayo level Ⅱ and 2 cases of level Ⅲ IVC thrombus with the mean IVC thrombus length of 6.5 cm(range 5-8cm). The "IVC-first, kidney-last" robotic technique was developed to minimize chances of IVC thrombus embolization for retrohepatic IVC thrombus, and a "artery-first, vein-second" robotic operative strategy were developed to minimize chances of intraoperative hemorrhage. The whole procedure (the suprahepatic infradiaphramatic IVC, first porta hepatis and left renal vein control, caval exclusion, tumor thrombectomy, IVC repair, radical nephrectomy) was performed exclusively robotically with a single position.Results:All 6 robotic procedures were successful, without open conversion or mortality. The mean operative time was 210 min(130-320 min), estimated blood loss was 800 ml(300-2 100 ml) and three patients (5%) received intraoperative blood transfusion. The mean time of occlusion of IVC was 21 min (15-43min). Incomplete blocking occurred in two cases(one IVC, one first porta hepatis), and tumor thrombectomy were completed with intraoperative loss. IVC invasion was confirmed intraoperatively in one patient and we staple-transected the IVC without reconstruction. Six patients were all transferred to the intensive care unit for median of 2.1 days (1-4 days) after surgery. The mean time of postoperative drainage was 5 days (4-9 days). Renal dysfunction occurred in 3 patients and liver dysfunction occurred in 2 patients, and all recovered after medical therapy. Postoperative pathological diagnosis revealed 5 cases of clear cell carcinoma and 1 case of renal sarcoma, and the 5 cases received targeted therapy. With a median follow-up of 27 months (3-54 months), 3 patients were alive, 1 alive with tumor recurrence, and 2 died of cancer.Conclusions:Robot-assisted laparoscopic retrohepatic IVC thrombectomy with a single position have the advantage of simple procedure, shorter operative time, less trauma and quicker recovery, and it is a feasible and effective method for renal tumor patients with retrohepatic IVC thrombus.

2.
Chinese Journal of Endocrine Surgery ; (6): 320-322, 2021.
Article in Chinese | WPRIM | ID: wpr-907800

ABSTRACT

Adrenal cortical adenocarcinoma is a rare and often aggressive malignant tumor. For ACC that originated outside the adrenal gland, there are few reports at home and abroad. We report a case of adrenocortical adenocarcinoma that originated from kidney, introduce its diagnosis, treatment and follow-up results in order to provide help for clinical diagnosis and treatment.

3.
Journal of Biomedical Engineering ; (6): 73-76, 2015.
Article in Chinese | WPRIM | ID: wpr-266724

ABSTRACT

Total hip replacement (THR) is replacing the prosthesis stem similar to human bone that takes advantage of the material with both good mechanical properties and biocompatibility to the damaged articular surface. Thus it can not only alleviate or even eliminate the pain but also effectively maintain the joint stability and freedom and restore its normal performance. Finite element analysis was used in this study to establish a 3D model of artificial hip stem, and explore its fatigue properties of different materials to ensure the safety and reliability. The calculating obtained two results of different metal hip prosthesis, including lifetime and deformation. The minimum service life of titanium prosthesis reaches 568 million times, which satisfies ISO standards, while the stainless steel does not suit to be a prosthesis material.


Subject(s)
Humans , Arthroplasty, Replacement, Hip , Finite Element Analysis , Hip Joint , Hip Prosthesis , Materials Testing , Models, Anatomic , Prosthesis Failure , Reproducibility of Results , Stainless Steel , Titanium
SELECTION OF CITATIONS
SEARCH DETAIL